All batteries
JYCHR
JYCAGM27 models
JYC HR High-rate AGM
For loads that need high output over a short time: UPS, server rooms, engine starting. Thanks to their grid and paste design, they deliver 30 % more power than the GP series.
- Voltage
- 12 V
- Power
- 28–870 W
- Models
- 27
Specifications
- Power
- 21–510 W per cell (15 min)
- Float service life
- 5–6 years at 25 °C
- Self-discharge
- ≤ 2 % per month
- Operating temperature
- −20…+50 °C
- Standards
- IEC 60896-21/22, IEC 61056-1/2, BS 6290-4
Where they are used
UPS and server roomsGenerator starting
HR series models
| Model | V | W/cell | L×W×H, mm | With terminal, mm | Weight, kg | Terminals | Price |
|---|---|---|---|---|---|---|---|
| HR1228W | 12 | 28 | 151×65×94 | 100 | 2.3 | F2 | |
| HR1233W | 12 | 33 | 151×65×94 | 100 | 2.4 | F2 | |
| HR1235W | 12 | 35 | 151×65×94 | 100 | 2.5 | F2 | |
| HR1237W | 12 | 37 | 151×65×94 | 100 | 2.6 | F2 | |
| HR1255W | 12 | 55 | 152×99×95 | 100 | 3.7 | F2 | |
| HR1290W | 12 | 90 | 182×77×167 | 167 | 5.9 | T1 | |
| HR12110W | 12 | 110 | 175×166×126 | 126 | 7.7 | T1 | |
| HR12112W | 12 | 112 | 165×126×173 | 173 | 8.4 | T2 | |
| HR12145W | 12 | 145 | 196×130×155 | 170 | 10.1 | T2 | |
| HR12165W | 12 | 165 | 198×167×173 | 173 | 12.5 | T2 | |
| HR12200W | 12 | 200 | 230×139×210 | 215 | 16 | T2 | |
| HR12260W | 12 | 260 | 348×168×177 | 177 | 20.8 | T3 | |
| HR12275W | 12 | 275 | 348×168×177 | 177 | 21.25 | T3 | |
| HR12300W | 12 | 300 | 260×169×213 | 219 | 24.1 | T3 | |
| HR12330W | 12 | 330 | 260×169×212 | 216 | 24.9 | T3 | |
| HR12360W | 12 | 360 | 306×168×210 | 214 | 28.6 | T4 | |
| HR12400W | 12 | 400 | 330×172×218 | 222 | 30.3 | T5 | |
| HR12405W | 12 | 405 | 306×168×210 | 214 | 29.5 | T4 | |
| HR12430W | 12 | 430 | 330×172×218 | 222 | 32.4 | T5 | |
| HR12460W | 12 | 460 | 406×173×208 | 233 | 36.2 | T5 | |
| HR12520W | 12 | 520 | 341×173×281 | 286 | 43.7 | T4 | |
| HR12560W | 12 | 560 | 481×170×242 | 245 | 43.8 | T5 | |
| HR12700W | 12 | 700 | 522×240×221 | 226 | 57.7 | T5 | |
| HR12730W | 12 | 730 | 522×240×221 | 226 | 59.9 | T5 | |
| HR12760W | 12 | 760 | 522×240×221 | 226 | 60.9 | T5 | |
| HR12800W | 12 | 800 | 522×240×221 | 226 | 63.5 | T5 | |
| HR12870W | 12 | 870 | 522×268×220 | 225 | 74.2 | T5 |
- HR1228W12 V · 28 W151×65×94 mm · 2.3 kg · F2
- HR1233W12 V · 33 W151×65×94 mm · 2.4 kg · F2
- HR1235W12 V · 35 W151×65×94 mm · 2.5 kg · F2
- HR1237W12 V · 37 W151×65×94 mm · 2.6 kg · F2
- HR1255W12 V · 55 W152×99×95 mm · 3.7 kg · F2
- HR1290W12 V · 90 W182×77×167 mm · 5.9 kg · T1
- HR12110W12 V · 110 W175×166×126 mm · 7.7 kg · T1
- HR12112W12 V · 112 W165×126×173 mm · 8.4 kg · T2
- HR12145W12 V · 145 W196×130×155 mm · 10.1 kg · T2
- HR12165W12 V · 165 W198×167×173 mm · 12.5 kg · T2
- HR12200W12 V · 200 W230×139×210 mm · 16 kg · T2
- HR12260W12 V · 260 W348×168×177 mm · 20.8 kg · T3
- HR12275W12 V · 275 W348×168×177 mm · 21.25 kg · T3
- HR12300W12 V · 300 W260×169×213 mm · 24.1 kg · T3
- HR12330W12 V · 330 W260×169×212 mm · 24.9 kg · T3
- HR12360W12 V · 360 W306×168×210 mm · 28.6 kg · T4
- HR12400W12 V · 400 W330×172×218 mm · 30.3 kg · T5
- HR12405W12 V · 405 W306×168×210 mm · 29.5 kg · T4
- HR12430W12 V · 430 W330×172×218 mm · 32.4 kg · T5
- HR12460W12 V · 460 W406×173×208 mm · 36.2 kg · T5
- HR12520W12 V · 520 W341×173×281 mm · 43.7 kg · T4
- HR12560W12 V · 560 W481×170×242 mm · 43.8 kg · T5
- HR12700W12 V · 700 W522×240×221 mm · 57.7 kg · T5
- HR12730W12 V · 730 W522×240×221 mm · 59.9 kg · T5
- HR12760W12 V · 760 W522×240×221 mm · 60.9 kg · T5
- HR12800W12 V · 800 W522×240×221 mm · 63.5 kg · T5
- HR12870W12 V · 870 W522×268×220 mm · 74.2 kg · T5
Not sure which battery you need?